MIL-PRF-914C (1)
RESISTOR NETWORKS, FIXED, FILM, SURFACE MOUNT, NONESTABLISHED RELIABILITY, AND ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR
Organization:
ARMY - CR - US Army Communications Electronics Command
Year: 2008
Abstract: This specification covers the general requirements for nonestablished reliability (non-ER) and established reliability (ER), hermetically sealed (see 3.27) and nonhermetically sealed networks (see 3.27.1). These networks consist entirely of fixed, film resistors. They are primarily intended for use in surface mount applications where space is a major concern. ER resistors covered by this specification will have life failure rates (FR) ranging from 1 percent to 0.001 percent per 1,000 hours (see 1.2.1.7). The ER FR are established at a minimum 60-percent confidence level on the basis of life tests. Designers are CAUTIONED on using these resistors in pulse applications (see 6.4.4).Intended Use: Networks described herein are intended to be used in surface mount applications.
Subject: Leadless chip carrier
Collections
:
-
Statistics
MIL-PRF-914C (1)
Show full item record
contributor author | ARMY - CR - US Army Communications Electronics Command | |
date accessioned | 2017-09-04T17:44:12Z | |
date available | 2017-09-04T17:44:12Z | |
date copyright | 39783 | |
date issued | 2008 | |
identifier other | EFJYKCAAAAAAAAAA.pdf | |
identifier uri | https://lib.yabesh.ir/std/handle/yse/167209 | |
description abstract | This specification covers the general requirements for nonestablished reliability (non-ER) and established reliability (ER), hermetically sealed (see 3.27) and nonhermetically sealed networks (see 3.27.1). These networks consist entirely of fixed, film resistors. They are primarily intended for use in surface mount applications where space is a major concern. ER resistors covered by this specification will have life failure rates (FR) ranging from 1 percent to 0.001 percent per 1,000 hours (see 1.2.1.7). The ER FR are established at a minimum 60-percent confidence level on the basis of life tests. Designers are CAUTIONED on using these resistors in pulse applications (see 6.4.4).Intended Use: Networks described herein are intended to be used in surface mount applications. | |
language | English | |
title | MIL-PRF-914C (1) | num |
title | RESISTOR NETWORKS, FIXED, FILM, SURFACE MOUNT, NONESTABLISHED RELIABILITY, AND ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR | en |
type | standard | |
page | 41 | |
status | Active | |
tree | ARMY - CR - US Army Communications Electronics Command:;2008 | |
contenttype | fulltext | |
subject keywords | Leadless chip carrier |