Show simple item record

Relief Valves for Hot Water Supply Systems - First Edition

contributor authorCSA/AM - CSA America, Inc.
date accessioned2017-09-04T18:00:41Z
date available2017-09-04T18:00:41Z
date copyright1999.04.01 (R 2004)
date issued2004
identifier otherAAZMIBAAAAAAAAAA.pdf
identifier urihttps://lib.yabesh.ir/std/handle/yse/183696
description abstractThis standard applies to the following types of relief valves constructed entirely of new, unused parts and materials:
a. Temperature relief valves and combination temperature and pressure relief valves for use on storage tanks of hot water supply systems without heater input limitation "T&P" valves, hereinafter called.
b. Valves having only pressure relief features for use on storage tanks of hot water supply systems without heater input limitation.
c. Vacuum relief valves.
A temperature relief valve, or a T&P valve shall operate when the temperature sensing element is at 210°F (99°C) or less. A device with a higher operating temperature is not acceptable under this Standard.
A vacuum relief valve shall be of a single-purpose type.
All references to psi throughout this standard are to be considered gage pressures unless otherwise specified.
Exhibit A contains provisions that are unique to Canada.
languageEnglish
titleCSA/AM ANSI Z21.22-1999/CSA 4.4-M99num
titleRelief Valves for Hot Water Supply Systems - First Editionen
typestandard
page76
statusRevised
treeCSA/AM - CSA America, Inc.:;2004