Show simple item record

Guidelines for specification and inspection of electric resistance welded (ERW) and seamless boiler tube for critical and noncritical service

contributor authorTAPPI - TAPPI
date accessioned2017-09-04T18:41:17Z
date available2017-09-04T18:41:17Z
date copyright2010.01.01
date issued2010
identifier otherJWUQPCAAAAAAAAAA.pdf
identifier urihttps://lib.yabesh.ir/std/handle/yse/222855
description abstractThis Technical Information Paper (TIP) covers guidelines to assure that boiler tubes for new construction and replacement, both in recovery and other boilers, are metallurgically sound and free from potentially harmful defects. Special emphasis is placed on obtaining tubing of appropriate quality for critical recovery boiler service. This service is defined as that in which tube leaks or failures can directly or indirectly lead to water reaching the smelt bed in the furnace, thereby creating the risk of explosion. Noncritical service encompasses all other recovery boiler tubing and power boiler tubing where leakage can result in increased safety risk or significant service interruption.
Boiler tube materials shown in this document are specified in the American Society for Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section II, Part A. Similar specifications are issued by the American Society for Testing and Materials (ASTM).
languageEnglish
titleTAPPI TIP 0402-13num
titleGuidelines for specification and inspection of electric resistance welded (ERW) and seamless boiler tube for critical and noncritical serviceen
typestandard
page8
statusActive
treeTAPPI - TAPPI:;2010
contenttypefulltext
subject keywordsBoiler tubes
subject keywordsInspection
subject keywordsNondestructive tests
subject keywordsQuality control