• 0
    • ارسال درخواست
    • حذف همه
    • Industrial Standards
    • Defence Standards
  • درباره ما
  • درخواست موردی
  • فهرست استانداردها
    • Industrial Standards
    • Defence Standards
  • راهنما
  • Login
  • لیست خرید شما 0
    • ارسال درخواست
    • حذف همه
View Item 
  •   YSE
  • Industrial Standards
  • NEMA - National Electrical Manufacturers Association
  • View Item
  •   YSE
  • Industrial Standards
  • NEMA - National Electrical Manufacturers Association
  • View Item
  • All Fields
  • Title(or Doc Num)
  • Organization
  • Year
  • Subject
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Archive

Electrical Submeter — General Requirements

NEMA ESM1-1

Organization:
NEMA - National Electrical Manufacturers Association
Year: 2019

Abstract: The requirements of this Standard cover metrological requirements and associated testing for electrical energy submeters. The Standard applies to stand-alone meters with Standard inputs or metering systems comprising meters and associated sensors. These meters provide details of energy use for energy monitoring or revenue submetering. The Standard does not apply to primary utility-owned meters. The Standard includes AC and DC kilowatt-hour meters, demand meters, load survey meters, and power quality meters, single and four-quadrant meters, etc. The Standard applies to indoor and outdoor applications and covers portable, permanently installed, and embedded meters. The Standard covers AC meters rated at not more than 1000 V that measure active energy, apparent energy, reactive energy (capacitive, inductive and/or total) including received, delivered, and/or net and also those measuring current, voltage, active power, apparent power, reactive power (capacitive, inductive and/or total), power factor, phase angle, polarity, and frequency when measured in addition to energy. The Standard also applies to DC meters rated not more than 1500 V that measure energy received, delivered, and/or net and also those that include additional measurement of power, current, and voltage. The ESM1 Standard is broken into the following parts: a. ESM1-1 General Requirements b. ESM1-2 AC Active Energy Accuracy c. ESM1-3 Revenue Submetering Requirements d. ESM1-4 Additional Measurements Accuracy e. ESM1-5 DC Energy Accuracy f. ESM1-6 Power Quality Measurements and Accuracy g. ESM1-7 Current Sensor Accuracy h. ESM1-8 Demand Metering i. ESM1-9 Field Testing
URI: https://lib.yabesh.ir/std/handle/yse/288583
Collections :
  • NEMA - National Electrical Manufacturers Association
  • Download PDF : (695.9Kb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Electrical Submeter — General Requirements

Show full item record

contributor authorNEMA - National Electrical Manufacturers Association
date accessioned2020-09-15T20:26:09Z
date available2020-09-15T20:26:09Z
date copyright2019
date issued2019
identifier otherPEKCMGAAAAAAAAAA.pdf
identifier otherPEKCMGAAAAAAAAAA.pdf
identifier urihttps://lib.yabesh.ir/std/handle/yse/288583
description abstractThe requirements of this Standard cover metrological requirements and associated testing for electrical energy submeters. The Standard applies to stand-alone meters with Standard inputs or metering systems comprising meters and associated sensors. These meters provide details of energy use for energy monitoring or revenue submetering. The Standard does not apply to primary utility-owned meters. The Standard includes AC and DC kilowatt-hour meters, demand meters, load survey meters, and power quality meters, single and four-quadrant meters, etc. The Standard applies to indoor and outdoor applications and covers portable, permanently installed, and embedded meters. The Standard covers AC meters rated at not more than 1000 V that measure active energy, apparent energy, reactive energy (capacitive, inductive and/or total) including received, delivered, and/or net and also those measuring current, voltage, active power, apparent power, reactive power (capacitive, inductive and/or total), power factor, phase angle, polarity, and frequency when measured in addition to energy. The Standard also applies to DC meters rated not more than 1500 V that measure energy received, delivered, and/or net and also those that include additional measurement of power, current, and voltage. The ESM1 Standard is broken into the following parts: a. ESM1-1 General Requirements b. ESM1-2 AC Active Energy Accuracy c. ESM1-3 Revenue Submetering Requirements d. ESM1-4 Additional Measurements Accuracy e. ESM1-5 DC Energy Accuracy f. ESM1-6 Power Quality Measurements and Accuracy g. ESM1-7 Current Sensor Accuracy h. ESM1-8 Demand Metering i. ESM1-9 Field Testing
languageEnglish
titleElectrical Submeter — General Requirementsen
titleNEMA ESM1-1num
typestandard
page34
statusActive
treeNEMA - National Electrical Manufacturers Association:;2019
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian