UFC 3-430-01FA

HEATING AND COOLING DISTRIBUTION SYSTEMS

Organization:
UFC - Unified Facilities Criteria
Year: 2003

Abstract: PURPOSE AND SCOPE.
This document provides criteria and guidance for the design and construction of heating and cooling distribution systems and supplements information in the "Notes to the Designer" of the guide specifications. These distribution systems include Heat Distribution Systems in Concrete Trenches, Pre-engineered Underground Heat Distribution Systems, Prefabricated Underground Heating/Cooling Distribution Systems, and Aboveground Heat Distribution Systems. The mediums used in these distribution systems, as defined by the Department of Defense (DoD), include:
a. High temperature hot water (HTHW) (251 deg. F to 450 deg. F)
b. Low temperature hot water (LTHW) (150 deg. F to 250 deg. F)
c. Low pressure steam systems (up to 15 psig)
d. High pressure steam systems (over 15 psig)
e. Condensate return systems (up to 200 deg. F)
f. Chilled water systems.
APPLICABILITY.
These instructions are applicable to all \2\ DoD agencies /2/ and their contractors involved in the design and construction of heating and cooling distribution systems.
URI: https://lib.yabesh.ir/std/handle/yse/35231
Collections :
  • UFC - Unified Facilities Criteria
  • Download PDF : (1.567Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UFC 3-430-01FA

Show full item record

contributor authorUFC - Unified Facilities Criteria
date accessioned2017-09-04T15:33:34Z
date available2017-09-04T15:33:34Z
date copyright07/25/2003
date issued2003
identifier otherOJYOJBAAAAAAAAAA.pdf
identifier urihttps://lib.yabesh.ir/std/handle/yse/35231
description abstractPURPOSE AND SCOPE.
This document provides criteria and guidance for the design and construction of heating and cooling distribution systems and supplements information in the "Notes to the Designer" of the guide specifications. These distribution systems include Heat Distribution Systems in Concrete Trenches, Pre-engineered Underground Heat Distribution Systems, Prefabricated Underground Heating/Cooling Distribution Systems, and Aboveground Heat Distribution Systems. The mediums used in these distribution systems, as defined by the Department of Defense (DoD), include:
a. High temperature hot water (HTHW) (251 deg. F to 450 deg. F)
b. Low temperature hot water (LTHW) (150 deg. F to 250 deg. F)
c. Low pressure steam systems (up to 15 psig)
d. High pressure steam systems (over 15 psig)
e. Condensate return systems (up to 200 deg. F)
f. Chilled water systems.
APPLICABILITY.
These instructions are applicable to all \2\ DoD agencies /2/ and their contractors involved in the design and construction of heating and cooling distribution systems.
languageEnglish
titleUFC 3-430-01FAnum
titleHEATING AND COOLING DISTRIBUTION SYSTEMSen
typestandard
page143
statusActive
treeUFC - Unified Facilities Criteria:;2003
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian