UFC 3-330-03A

SEISMIC REVIEW PROCEDURES FOR EXISTING MILITARY BUILDINGS

Organization:
UFC - Unified Facilities Criteria
Year: 2005

Abstract: (1) Basis of procedures. The seismic review procedures for structural systems were developed by modifying the screening procedures in FEMA 154.
(2) Application. The procedures in this document are intended only for the purposes indicated above, and are not intended to supersede or replace the provisions of TI 809-05 for the evaluation and rehabilitation of military buildings.
(3) Limitations. Review of site-specific seismic geologic hazards and nonstructural components and systems is beyond the scope of these procedures.
Purpose.
The purpose of this document is to provide procedures for the assessment of the relative seismic vulnerability of a large inventory of buildings at a military installation. The structural systems of each building or groups of structurally similar buildings in the inventory are reviewed to obtain a numerical score. The scores obtained for all buildings or groups in the inventory are recorded in numerical order in an Installation Report to provide a numerical ranking of the seismic vulnerability of the buildings. This ranked list will provide a basis by which military installations can determine the order for performing seismic evaluations. Other building-specific aspects to consider in conjunction with this review should include: general condition, known site-specific seismic geologic hazards, occupancy type, number of occupants, year built, plans for future use, and availability of alternative buildings (redundancy of function).
Applicability.
These instructions are applicable to all USACE elements and their contractors assessing buildings for seismic vulnerability at military installations.
URI: https://lib.yabesh.ir/std/handle/yse/38240
Collections :
  • UFC - Unified Facilities Criteria
  • Download PDF : (3.649Mb)
  • Show Full MetaData Hide Full MetaData
  • Statistics

    UFC 3-330-03A

Show full item record

contributor authorUFC - Unified Facilities Criteria
date accessioned2017-09-04T15:36:13Z
date available2017-09-04T15:36:13Z
date copyright03/01/2005
date issued2005
identifier otherORZOJBAAAAAAAAAA.pdf
identifier urihttps://lib.yabesh.ir/std/handle/yse/38240
description abstract(1) Basis of procedures. The seismic review procedures for structural systems were developed by modifying the screening procedures in FEMA 154.
(2) Application. The procedures in this document are intended only for the purposes indicated above, and are not intended to supersede or replace the provisions of TI 809-05 for the evaluation and rehabilitation of military buildings.
(3) Limitations. Review of site-specific seismic geologic hazards and nonstructural components and systems is beyond the scope of these procedures.
Purpose.
The purpose of this document is to provide procedures for the assessment of the relative seismic vulnerability of a large inventory of buildings at a military installation. The structural systems of each building or groups of structurally similar buildings in the inventory are reviewed to obtain a numerical score. The scores obtained for all buildings or groups in the inventory are recorded in numerical order in an Installation Report to provide a numerical ranking of the seismic vulnerability of the buildings. This ranked list will provide a basis by which military installations can determine the order for performing seismic evaluations. Other building-specific aspects to consider in conjunction with this review should include: general condition, known site-specific seismic geologic hazards, occupancy type, number of occupants, year built, plans for future use, and availability of alternative buildings (redundancy of function).
Applicability.
These instructions are applicable to all USACE elements and their contractors assessing buildings for seismic vulnerability at military installations.
languageEnglish
titleUFC 3-330-03Anum
titleSEISMIC REVIEW PROCEDURES FOR EXISTING MILITARY BUILDINGSen
typestandard
page64
statusActive
treeUFC - Unified Facilities Criteria:;2005
contenttypefulltext
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian
 
DSpace software copyright © 2017-2020  DuraSpace
نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
yabeshDSpacePersian