Abstract: This test method is designed to determine the corrosive properties of flux residues under extreme environmental conditions. A pellet of solder is melted in contact with the test flux on a sheet metal test piece. The solder is then exposed to prescribed conditions of humidity and the resulting corrosion, if any, is assessed visually.
Collections
:
-
Statistics
IPC TM-650 2.6.15C
Show full item record
contributor author | IPC - Association Connecting Electronics Industries | |
date accessioned | 2017-09-04T16:49:35Z | |
date available | 2017-09-04T16:49:35Z | |
date copyright | 06/01/2004 | |
date issued | 2004 | |
identifier other | WLLGIBAAAAAAAAAA.pdf | |
identifier uri | https://lib.yabesh.ir/std/handle/yse/113095 | |
description abstract | This test method is designed to determine the corrosive properties of flux residues under extreme environmental conditions. A pellet of solder is melted in contact with the test flux on a sheet metal test piece. The solder is then exposed to prescribed conditions of humidity and the resulting corrosion, if any, is assessed visually. | |