TIA TIA-455-187
FOTP-187 Engagement and Separation Force Measurement of Fiber Optic Connector Sets - ANSI APPROVAL WITHDRAWN MARCH, 2004
Organization:
TIA - Telecommunications Industry Association
Year: 1991
Abstract: INTRODUCTION
Intent
The purpose of this procedure is to measure the forces or torques that are required to fully couple or uncouple a connector set.
Description
The connector set components are held in a fixture so that a controlled coupling force or torque can be applied. The force or torque is measured during the entire coupling and/or uncoupling cycle. The procedure is applicable to either twist type or push-pull type coupling mechanisms.
Alternative Procedures
This test procedure is an alternative to the measurement procedure, titled Engagement and Separation Force of IEC 874-1, Third Edition.
Intent
The purpose of this procedure is to measure the forces or torques that are required to fully couple or uncouple a connector set.
Description
The connector set components are held in a fixture so that a controlled coupling force or torque can be applied. The force or torque is measured during the entire coupling and/or uncoupling cycle. The procedure is applicable to either twist type or push-pull type coupling mechanisms.
Alternative Procedures
This test procedure is an alternative to the measurement procedure, titled Engagement and Separation Force of IEC 874-1, Third Edition.
Collections
:
-
Statistics
TIA TIA-455-187
Show full item record
| contributor author | TIA - Telecommunications Industry Association | |
| date accessioned | 2017-09-04T15:13:00Z | |
| date available | 2017-09-04T15:13:00Z | |
| date copyright | 07/01/1991 | |
| date issued | 1991 | |
| identifier other | LZACJAAAAAAAAAAA.pdf | |
| identifier uri | https://lib.yabesh.ir/std/handle/yse/11597 | |
| description abstract | INTRODUCTION Intent The purpose of this procedure is to measure the forces or torques that are required to fully couple or uncouple a connector set. Description The connector set components are held in a fixture so that a controlled coupling force or torque can be applied. The force or torque is measured during the entire coupling and/or uncoupling cycle. The procedure is applicable to either twist type or push-pull type coupling mechanisms. Alternative Procedures This test procedure is an alternative to the measurement procedure, titled Engagement and Separation Force of IEC 874-1, Third Edition. | |
| language | English | |
| title | TIA TIA-455-187 | num |
| title | FOTP-187 Engagement and Separation Force Measurement of Fiber Optic Connector Sets - ANSI APPROVAL WITHDRAWN MARCH, 2004 | en |
| type | standard | |
| page | 12 | |
| status | Active | |
| tree | TIA - Telecommunications Industry Association:;1991 | |