IPC TM-650 2.5.7D
Dielectric Withstanding Voltage, PCB
Organization:
IPC - Association Connecting Electronics Industries
Year: 2004
Abstract: The dielectric withstanding voltage test (also called high-potential, over potential, voltage breakdown, or dielectric strength test) consists of the application of a voltage higher than rated voltage for a specific time between mutually isolated portions of a PCB or between isolated portions and ground. This is used to prove that the PCB can operate safely at its rated voltage and withstand momentary over potentials due to switching, surges, and other similar phenomena. Although this test is often called a voltage breakdown or dielectric strength test, it is not intended that this test cause insulation breakdown or that it be used for detecting corona, rather it serves to determine whether insulating materials and/or conductor spacings are adequate.
Collections
:
-
Statistics
IPC TM-650 2.5.7D
Show full item record
contributor author | IPC - Association Connecting Electronics Industries | |
date accessioned | 2017-09-04T16:55:57Z | |
date available | 2017-09-04T16:55:57Z | |
date copyright | 05/01/2004 | |
date issued | 2004 | |
identifier other | XCPHFBAAAAAAAAAA.pdf | |
identifier uri | https://lib.yabesh.ir/std/handle/yse/119385 | |
description abstract | The dielectric withstanding voltage test (also called high-potential, over potential, voltage breakdown, or dielectric strength test) consists of the application of a voltage higher than rated voltage for a specific time between mutually isolated portions of a PCB or between isolated portions and ground. This is used to prove that the PCB can operate safely at its rated voltage and withstand momentary over potentials due to switching, surges, and other similar phenomena. Although this test is often called a voltage breakdown or dielectric strength test, it is not intended that this test cause insulation breakdown or that it be used for detecting corona, rather it serves to determine whether insulating materials and/or conductor spacings are adequate. | |
language | English | |
title | IPC TM-650 2.5.7D | num |
title | Dielectric Withstanding Voltage, PCB | en |
type | standard | |
page | 2 | |
status | Active | |
tree | IPC - Association Connecting Electronics Industries:;2004 | |
contenttype | fulltext |