NEMA C82.4
For Lamp Ballasts - Ballasts for High-Intensity-Discharge and Low-Pressure Sodium Lamps (Multiple-Supply Type)
Organization:
NEMA - National Electrical Manufacturers Association
Year: 2002
Abstract: This standard provides specifications for and operating characteristics of ballasts for mercury, metal-halide, high-pressure sodium (HPS), and low-pressure sodium (LPS) lamps. The ballasts operate from multiple-supply sources of 600 volts maximum at a frequency of 60 hertz. They may be designed for operation under either indoor or outdoor conditions.
The following types of ballasts are excluded from this standard:
(1) Ballasts consisting of resistance only
(2) Transformers for constant current (series) operation of mercury lamps (see American National Standard for Mercury Lamp Transformers - Constant Current (Series) Supply Type, ANSI C82.7-1983 (R1988)
(3) All ballasts that use semiconductors to control the lamp power.
The following types of ballasts are excluded from this standard:
(1) Ballasts consisting of resistance only
(2) Transformers for constant current (series) operation of mercury lamps (see American National Standard for Mercury Lamp Transformers - Constant Current (Series) Supply Type, ANSI C82.7-1983 (R1988)
(3) All ballasts that use semiconductors to control the lamp power.
Collections
:
Show full item record
contributor author | NEMA - National Electrical Manufacturers Association | |
date accessioned | 2017-09-04T17:08:24Z | |
date available | 2017-09-04T17:08:24Z | |
date copyright | 01/01/2002 | |
date issued | 2002 | |
identifier other | YKJBYAAAAAAAAAAA.pdf | |
identifier uri | https://lib.yabesh.ir/std/handle/yse/131944 | |
description abstract | This standard provides specifications for and operating characteristics of ballasts for mercury, metal-halide, high-pressure sodium (HPS), and low-pressure sodium (LPS) lamps. The ballasts operate from multiple-supply sources of 600 volts maximum at a frequency of 60 hertz. They may be designed for operation under either indoor or outdoor conditions. The following types of ballasts are excluded from this standard: (1) Ballasts consisting of resistance only (2) Transformers for constant current (series) operation of mercury lamps (see American National Standard for Mercury Lamp Transformers - Constant Current (Series) Supply Type, ANSI C82.7-1983 (R1988) (3) All ballasts that use semiconductors to control the lamp power. | |
language | English | |
title | NEMA C82.4 | num |
title | For Lamp Ballasts - Ballasts for High-Intensity-Discharge and Low-Pressure Sodium Lamps (Multiple-Supply Type) | en |
type | standard | |
page | 20 | |
status | Active | |
tree | NEMA - National Electrical Manufacturers Association:;2002 | |
contenttype | fulltext |