Abstract: The standards in this part apply to magnetically-operated, full-voltage vacuum-break, noncombination controllers rated 1500 volts for both motor and non-motor loads. The motor-rated controllers are full-voltage for use with squirrel-cage and wound-rotor induction motors. The nonmotor loads may be single or three-phase transformer, capacitor, heating or lighting loads.
PURPOSE
The purpose of this part is to establish standard ratings, marking, construction, and performance requirements for Class V vacuum-break controllers and provide a means to evaluate other vacuum-break controllers which do not qualify for designation as a Class V controller.
PURPOSE
The purpose of this part is to establish standard ratings, marking, construction, and performance requirements for Class V vacuum-break controllers and provide a means to evaluate other vacuum-break controllers which do not qualify for designation as a Class V controller.
Collections
:
Show full item record
contributor author | NEMA - National Electrical Manufacturers Association | |
date accessioned | 2017-09-04T18:07:33Z | |
date available | 2017-09-04T18:07:33Z | |
date copyright | 01/01/2002 (R 2013) | |
date issued | 2013 | |
identifier other | GPDDDFAAAAAAAAAA.pdf | |
identifier uri | https://lib.yabesh.ir/std/handle/yse/190450 | |
description abstract | The standards in this part apply to magnetically-operated, full-voltage vacuum-break, noncombination controllers rated 1500 volts for both motor and non-motor loads. The motor-rated controllers are full-voltage for use with squirrel-cage and wound-rotor induction motors. The nonmotor loads may be single or three-phase transformer, capacitor, heating or lighting loads. PURPOSE The purpose of this part is to establish standard ratings, marking, construction, and performance requirements for Class V vacuum-break controllers and provide a means to evaluate other vacuum-break controllers which do not qualify for designation as a Class V controller. | |
language | English | |
title | NEMA ICS 2.9 | num |
title | Industrial Automation Control Products and Systems: Starters, Contactors, and Overload Relays Rated not more than 2000 Volts AC or 750 Volts DC - Part 9 AC Vacuum-Break Magnetic Controllers Rated 1500 Volts AC | en |
type | standard | |
page | 48 | |
status | Active | |
tree | NEMA - National Electrical Manufacturers Association:;2013 | |
contenttype | fulltext |